• PROFINET 2x2x22 m㎡
PROFINET 2x2x22 m㎡
+

Share to

PROFINET 2x2x22 m㎡

Flexible installation on and below deck of commercial ships without constant exposure to oil, grease and other lubricants. The cables meet the technical requirements of IEC 61158-2, IEC 60092-360.

Still deciding? Get samples first,  Contact US !

  • Description
  • Application
    Flexible installation on and below deck of commercial ships without constant exposure to oil, grease and other lubricants. The cables meet the technical requirements of IEC 61158-2, IEC 60092-360.


    Construction

    Conductor

    Stranded bare copper, AWG 22 (0.34mm2)

    Insulation

    Polyethylene(Ø1.59mm)

    No. of core

    4

    Insulation color

    White, Yellow, Blue, Orange,

    Shield

    Al. /polyester tape

    Screen

    Tinned copper wire braid

    Outer jacket

    SHF1 or SHF2 or SHF2 MUD

    Outer jacket color

    Green or per request

    Outer diameter  

    6.0 ± 0.5 mm

     

    Electrical characteristic(@20℃)

    Conductor DC resistance

    ≤59.4 Ohm/100m

    Mutual capacitance

    ≤5.6 nF/100m

    Dielectric strength(Between conductors)

    DC1.0Kv, 1min no broken

    Transmission Frequency (MHZ) 

    1

    4

    8

    10

    16

    20

    25

    31.25

    62.5

    100

    NEXT dB/100m

    65.3

    56.3

    51.8

    50.3

    47.2

    45.8

    44.3

    42.9

    38.4

    35.3

    Attenuation dB/100m

    2.1

    4.1

    5.8

    6.5

    8.3

    9.3

    10.4

    11.7

    17.0

    22.0

    Characteristic Impedance(MHz)

    100 ± 15

     

    Environmental properties and fire performances

    Halogen free

    IEC 60754-1&2

    Smoke-density

    IEC 61034-2

    Flame retardant

    IEC 60332-3-22 and IEC 60332-1-2

    Oil resistant

    IEC 60092-360

    UV resistant

    UL 1581

    Fire resistant(optional)

    IEC 60331-23

     

    Mechanical characteristics

    Temperature (operation)

    -40 to + 85 °C

    Temperature (installation)

    -15 to + 50 °C

    Minimum bending radius (operation)

    10 x O.D.

    Minimum bending radius (installation)

    20 x O.D.

PROFINET 2x2x22 m㎡

Flexible installation on and below deck of commercial ships without constant exposure to oil, grease and other lubricants. The cables meet the technical requirements of IEC 61158-2, IEC 60092-360.

Still deciding? Get samples first,  Contact US !

Inquire Now

We will contact you within one working day. Please pay attention to your email.

Send form