    Construction

    Conductor

    Stranded tinned Cu (0.22mm²)

    Insulation

    Polyolefin Ø1.46 mm

    No. of pair

    2 pair

    Insulation color

    White & Blue, Green & Red

    Screen

    Per pair 100% Al-/polyester tape

    Filler

    LSZH

    Shield

    Tinned copper braid ≥80%

    Inner jacket

    SHF1

    Armour

    Galvanized steel wire braid (GSWB) or Tinned copper wire braid (TCWB)

    Outer jacket

    SHF1 or SHF2 or SHF2 MUD

    Outer jacket color

    Black or per request

    Outer diameter  

    6.6 ± 0.5 mm

     

    Electrical characteristic(@20℃)

    Conductor DC resistance

    ≤ 90.0 Ohm/km

    Insulation resistance

    ≥5000 MΩ.m

    Operation voltage

    100 V

    Test voltage

    1000V DC 1 Min

    Nominal capacitance at 1kHz

    42 pF/m

    Characteristic impedance Zo

    105~135Ω @ 1 MHz

    Nominal attenuation

    22.0 dB/km

     

    Environmental properties and fire performances

    Halogen free

    IEC 60754-1&2

    Smoke-density

    IEC 61034-1&2

    Flame retardant

    IEC 60332-3-22 and IEC 60332-1-2

    Oil resistant

    IEC 60092-360

    UV resistant

    UL 1581

    Fire resistant(optional)

    IEC 60331-23

     

    Mechanical characteristics

    Temperature (operation)

    -40 to + 90 °C

    Temperature (installation)

    -15 to + 50 °C

    Minimum bending radius (operation)

    10 x O.D.

    Minimum bending radius (installation)

    20 x O.D.