Application
High performance Ethernet cable for shipboard and offshore installations. Apply to general wiring system, Including 10/100/1000 Base-T, 10G, ATM & Token Ring. This range of armoured cables is designed to support Cat 6A Link and Channel performance. With internationally defined Physical and Electrical performance up to 500MHz. Armour by galvanized steel wire braid is applied over the inner jacket for an improved mechanical resistance.
Construction
|
Conductor
|
Solid bare copper, AWG 23(0.246mm2)
|
|
Insulation
|
Foam polyethylene (Nom. Ø1.30mm)
|
|
No. of pair
|
4
|
|
Insulation color
|
White/Blue, White/Orange, White/Green, White/Brown
|
|
Individual screen
|
Per pair 100% Al-/polyester tape
|
|
Overall screen
|
Tinned copper wire braid
|
|
Inner jacket
|
SHF1 or SHF2
|
|
Armour
|
Galvanized steel wire braid (GSWB) or Tinned copper wire braid (TCWB)
|
|
Outer jacket
|
SHF1 or SHF2 or SHF2 MUD
|
|
Outer jacket color
|
Grey or per request
|
|
Outer diameter
|
11.4 ± 0.8 mm
|
Standards
BS EN 50288-4, TIA-568.2-D, IEC 61156-5, ISO/IEC11801.
Electrical characteristic(@20℃)
|
Conductor DC resistance
|
≤78 Ohm/km
|
|
Velocity factor
|
74%
|
|
Conductor resistance unbalance within pair
|
≤2%
|
|
Conductor resistance unbalance between pair
|
≤4%
|
|
Insulation resistance
|
≥5000 MΩ.m
|
|
Mean characteristic impedance
|
100 ± 5 ohm @100MHz
|
|
Dielectric strength(conductor/conductor)
|
1.0KV d.c for 1min
|
|
Dielectric strength(conductor/screen)
|
1.0KV d.c for 1min
|
|
Transfer impedance
|
Grade Ⅰ
|
|
Transmission frequency (MHZ)
|
1
|
4
|
10
|
16
|
20
|
31.25
|
62.5
|
100
|
200
|
250
|
400
|
500
|
|
Attenuation dB/100m
|
/
|
3.8
|
5.9
|
7.5
|
8.4
|
10.5
|
15.0
|
19.1
|
27.6
|
31.1
|
40.1
|
45.3
|
|
Return loss dB/100m
|
20
|
23
|
25
|
25
|
25
|
23.6
|
21.5
|
20.1
|
18.0
|
17.3
|
17.3
|
17.3
|
|
NEXT dB/100m
|
75.3
|
66.3
|
60.3
|
57.2
|
55.8
|
52.9
|
48.4
|
45.3
|
40.8
|
39.3
|
36.3
|
34.8
|
|
PS NEXT dB/100m
|
72.3
|
63.3
|
57.3
|
54.2
|
52.8
|
49.9
|
45.4
|
42.3
|
37.8
|
36.3
|
33.3
|
31.8
|
|
ACR-F dB/100m
|
68
|
56
|
48
|
43.9
|
42
|
38.1
|
32.1
|
28
|
22
|
20
|
16
|
14
|
|
PS ACR-F dB/100m
|
65
|
53
|
45
|
40.9
|
39
|
35.1
|
29.1
|
25
|
19
|
17
|
13
|
11
|
|
Delay ns/100m
|
570
|
552
|
545
|
543
|
542
|
540
|
539
|
538
|
537
|
536
|
536
|
536
|
|
Skew ns/100m
|
≤45
|
Environmental properties and fire performances
|
Halogen free
|
IEC 60754-1&2
|
|
Smoke-density
|
IEC 61034-1&2
|
|
Flame retardant
|
IEC 60332-3-22 and IEC 60332-1-2
|
|
Oil resistant
|
IEC 60092-360
|
|
UV resistant
|
UL 1581
|
|
Fire resistant(optional)
|
IEC 60331-23
|
Mechanical characteristics
|
Temperature (operation)
|
-40 to + 85 °C
|
|
Temperature (installation)
|
-15 to + 50 °C
|
|
Minimum bending radius (operation)
|
10 x O.D.
|
|
Minimum bending radius (installation)
|
20 x O.D.
|