Contact

Email:
sales@hymanoffshore.com

Phone:
+86 21 5807 0279/0310/0321/0351

Address:
No. 6, Factory Building No. 5, Hangfan Road, Damaiwan Industrial Zone, Hangtou Town, Pudong New Area, Shanghai, China, Postal Code: 201316

Grenada CAT7 -7 AWG Armour

High performance Ethernet cable for shipboard and offshore installations. Apply to general wiring system, including 10/100/1000 Base-T, 10G, ATM & Token Ring. This range of armoured cables is designed to support Cat7 Link and Channel performance. With internationally defined Physical and Electrical performance up to 600MHz. Armour by galvanized steel wire braid is applied over the inner jacket for an improved mechanical resistance.

Category:

GrenadaNetwork Cable

Send an email

Product Description

Application
High performance Ethernet cable for shipboard and offshore installations. Apply to general wiring system, Including 10/100/1000 Base-T, 10G, ATM & Token Ring. This range of armoured cables is designed to support Cat7 Link and Channel performance. With internationally defined Physical and Electrical performance up to 600MHz. Armour by galvanized steel wire braid is applied over the inner jacket for an improved mechanical resistance.


Construction

Conductor

Stranded bare copper, AWG 23(0.246mm2)

Insulation

Foam polyethylene (Nom. Ø1.41mm)

No. of pair

4

Insulation color

White/Blue, White/Orange, White/Green, White /Brown

Individual screen

Per pair 100% Al-/polyester tape

Overall screen

Tinned copper wire braid

Inner jacket

SHF1 or SHF2

Armour

Galvanized steel wire braid (GSWB) or Tinned copper wire braid (TCWB)

Outer jacket

SHF1 or SHF2 or SHF2 MUD

Outer diameter  

11.4 ± 0.8 mm

Outer jacket color

Grey or per request

 

Standards
BS EN 50288-4, UL Subject 444, IEC 61156-5, ISO/IEC11801.


Electrical characteristic(@20℃)

Conductor DC resistance

≤78 Ohm/km

Velocity factor

74%

Conductor resistance unbalance within pair

≤2%

Conductor resistance unbalance between pair

≤4%

Insulation resistance

≥5000 MΩ.m

Mean characteristic impedance

100 ± 5 ohm @100MHz

Dielectric strength(conductor/conductor)

1.0KV d.c for 1min

Dielectric strength(conductor/screen)

1.0KV d.c for 1min

Transfer impedance

Grade Ⅰ

Transmission

frequency (MHZ)

1

4

10

16

20

30

62.5

100

155

200

250

300

600

Attenuation dB/100m

/

3.7

5.9

7.4

8.3

10.2

14.9

19.0

24.0

27.5

31.0

34.2

50.1

Return loss dB/100m

20

23

25

25

25

23.8

21.5

20.1

18.8

18.0

17.3

17.3

17.3

NEXT dB/100m

78

78

78

78

78

78

75.5

72.4

69.5

67.9

66.4

65.2

60.7

PS NEXT dB/100m

75

75

75

75

75

75

72.5

69.4

66.5

64.9

63.4

62.2

57.7

ACR-F dB/100m

78

78

74

69.9

68

64.5

58.1

54

50.2

48.0

46

44.5

38.4

PS ACR-F dB/100m

75

75

71

66.9

65.0

61.5

55.1

51.0

47.2

45.0

43.0

41.5

35.4

Delay ns/100m

570

552

545

543

542

541

539

538

537

537

536

536

536

Skew ns/100m

≤25

 

Environmental properties and fire performances

Halogen free

IEC 60754-1&2

Smoke-density

IEC 61034-1&2

Flame retardant

IEC 60332-3-22 and IEC 60332-1-2

Oil resistant

IEC 60092-360

UV resistant

UL 1581

Fire resistant(optional)

IEC 60331-23

 

Mechanical characteristics

Temperature (operation)

-40 to + 85 °C

Temperature (installation)

-15 to + 50 °C

Minimum bending radius (operation)

10 x O.D.

Minimum bending radius (installation)

20 x O.D.